DANFOSS EKC 102A PDF

Danfoss EKCA Volt. Electronic Temperature Controller. VA. 50 / 60Hz. Operating Range ° C – 99 ° C. For Refrigeration Applications and. Temperature controller. EKC MAKING MODERN LIVING POSSIBLE ON/ OFF thermostat. • Sensors: Danfoss Pt, PTC or NTC EKC A. 0: None, defrost is based on time EKC A: 1=Sair EKC B: 1=Sair. EKC C .. EN and EN , A2 Weight = g Danfoss can accept no.

Author: Kazishicage Kamuro
Country: Albania
Language: English (Spanish)
Genre: Software
Published (Last): 13 November 2004
Pages: 141
PDF File Size: 12.14 Mb
ePub File Size: 18.88 Mb
ISBN: 530-6-87533-590-9
Downloads: 18376
Price: Free* [*Free Regsitration Required]
Uploader: Dugami

See the significance in the Fault Message section. This page uses cookie files to provide its services in accordance to Cookies Usage Policy. After two seconds you can move back into the mennu again and check whether the copying was satisfactory. Interval between defrost starts The function is zeroset and will start the timer function at each defrost start. The set danfiss can be locked or limited to a range with the settings in r02 and r Danfoss reserves the right to alter its products without notice.

Roof mounted industrial Electrical defrosting air cooler low temperature DJ series for cold room.

HVAC Danfoss Electronic Temperature Controller type Danfoss EKC A B for Freezer

If the time is passed, a defrost will be started. Amazon Restaurants Food delivery from local restaurants. The temperature value is set. English Choose a language for shopping.

  CAMILLA FANNY BURNEY PDF

With only two keys, all functions can be set and programmed. The limit value will be wkc during night operation. There is no sensor -d-: Share your thoughts with other customers. The contact will cut in when refrigeration step 2 has to be cut in Defrost.

Item is in your Cart.

Buttons and packing are imbedded in the front. DO3 is a 8 A relay.

Controller for temperature control – EKC Manual |

Copying key not correctly mounted 5: Normal display Normal display shows the temperature value from the thermostat sensor Sair. Faults in the controller E Sensor error on Sair E OFF-time in minutes Time delay for couplings of two compressors Settings indicate the time that has to elapse from the first relay cuts in and until the next relay has to cut in. We will reply as soon as possible. EKC B Controller with two relay outputs, extra temperature sensor and digital input.

Off when DI is open. A measurement of the 102x temperature can be obtained directly through the use of an S5 sensor.

Copying concluded and OK 4: The display shows the actual room temperature, but by activating the keys the display changes To the set or the actual temperature of the defrost sensor.

This function can only be used in 1: When the compressor is operating it must run for at least x minutes.

  HANYU TINGLI JIAOCHENG PDF

Amazon Drive Cloud storage from Amazon. When there is an alarm all the light-emitting diodes LED will flash on the controller front panel Alarm delay short alarm delay If one of the two limit values is exceeded, a timer function will commence. Access code 2 partly access Save the controllers present settings rkc the programming key.

Copy from the programming key This function downloads a set of settings earlier saved in the controller. Don’t see what you’re looking for? This happens when the temperature reaches the upper part of the differential.

Controller for temperature control – EKC 102 Manual

The Danfoss controller is used for applications where temperature is critical. Refrigeration compressor or solenoid valve Defrost Alarm Refrigeration 2 compressor 2 Advantages: R22 Medium and high temperature scroll air-cooled condensing unit Open air outlet from side scroll ZB series.

It will cut out again when the temperature comes down to the set reference. The controller is used for temperature control refrigeration appliances and cold room Defrost control For front panel mounting Principle: Upper alarm limit Here you set when the alarm for high temperature is to start.